System Properties
 
1. Wiserfence works with most alarm systems in the current market.
2. Input voltage from an integrated alarm system.
3. A modular system allowing usage options in 4-8 linear regions.
4. Option to connect multiple Wiserfence systems together, to
   expand the number of regions.
5. Simple and user-friendly operation.
6. Several mechanisms to prevent false alarms.
7. Options to set the sensitivity of each area separately.
8.  system to neutralize effects of the weather.
9. Warning against short circuit or disconnection of the line or
     sensors, or sabotage.
10. indicators for problems and various other events in
       each individual area protected by the Wiserfence system.
11. Indicators for different events and system status on a board
       integrated into the alarm system.
12. Option for topographic display on the computer screen in addition
       to the interface circuit.
 
Technical Details
 
Each zone card protects a section of fence, of length 3-200 meters, although the recommended length of section is approximately 50 meters.
Display  system – Shows events on the fence, followed by the nature of the events. Analyses that this is not a one-time alarm, and ensures it is a genuine alarm. Short/ disconnection indicator.
 
Technical Details
 
1. Voltage in: 12V/ 1A
2. Minimum working voltage: 9V
3. Maximum working voltage: 15V.
4. Backup battery: 12VDC/ 7AH. Charging voltage: 13.8V
5. Working temperature: -30°C – +60°C 
6. Outputs: 1A N.C.1 relay for entry of areas into system from all areas
                  A topographic map is displayed on the cell phone
7. Inputs: 8 wired sensors lines per analyzer circuit.
8. Maximal recommended distance of 2km between detectors and system.
9. Recommended sensor line length up to 50 meters.
 
Wiserfence controller connects easily to different types of home and industrial alarm systems, that can be found in the market